Overview of alarms 06/2009
NCK alarms
2-78
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Alarm display.
Remedy: Please inform the authorized personnel/service department. Reduce the number of variables, reduce
the size of arrays, or increase the capacity of the data management system.
- If new macro definitions are to be introduced -> Increase MD18160
$MN_MM_NUM_USER_MACROS
- If new GUD definitions are to be introduced -> Check MD18150 $MN_MM_GUD_VALUES_MEM,
MD18130 $MN_MM_NUM_GUD_NAMES_CHAN, MD18120 $MN_MM_NUM_GUD_NAMES_NCK
- If the error occurs while executing an NC program with LUD definitions or when using cycle programs
(the parameters count as LUD variable of the cycle program), the following machine data must be
checked:
MD28040 $MC_MM_LUD_VALUES_MEM,
MD18242 $MN_MM_MAX_SIZE_OF_LUD_VALUE,
MD18260 $MN_MM_LUD_HASH_TABLE_SIZE,
MD28020 $MC_MM_NUM_LUD_NAMES_TOTAL,
MD28010 $MC_MM_NUM_REORG_LUD_MODULES
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12390 [Channel %1: ] Block %2 initialization value %3 cannot be converted
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: During initialization, a value has been assigned to a variable that does not correspond to the type of
the variable, nor can it be converted to the data type of the variable.
Overview of type conversions:
- from REAL to REAL: no, INT: yes1), BOOL: yes, CHAR: yes2), STRING: -
- from INT to REAL: yes, INT: no, BOOL: yes, CHAR: yes2), STRING: -
- from BOOL to REAL: yes, INT: yes, BOOL: no, CHAR: yes, STRING: -
- from CHAR to REAL: yes, INT: yes, BOOL: yes, CHAR: no, STRING: yes
- from STRING to REAL: -, INT: -, BOOL: yes, CHAR: yes3), STRING: no
1) Value <> 0 corresponds to TRUE, value ==0 corresponds to FALSE.
2) String length 0 => FALSE, otherwise TRUE.
3) If only one character.
It is not possible to convert from type AXIS and FRAME nor into type AXIS and FRAME.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
- Define variable type such that the initialization value can be assigned, or
- Select initialization value in accordance with the variable definition.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12400 [Channel %1: ] Block %2 field %3 element does not exist
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: The following causes are possible:
- Impermissible index list; an axis index is missing
- Array index does not match the definition of the variables
- An attempt was made to access a variable at array initialization via SET or REP; this attempt did not
correspond to the standard access. Single character access, partial frame access, omitted indices not
possible.
A non-existent element was addressed on initializing this array.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.