Overview of alarms 06/2009
Cycle alarms
2-212
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61192 [Channel %1: ] Block %2: second 5 axis transformation not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61193 [Channel %1: ] Block %2: compressor option not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61194 [Channel %1: ] Block %2: spline interpolation option not set up
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The alarm is triggerd by the following cycles: CYCLE832.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61196 [Channel %1: ] Block %2: no swiveling in JOG --> 5 axis transformation
and TCARR simultaneously activated
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: 5-axis transformation and TOOLCARRIER activated at the same time.
Alarm triggered by following cycles: CYCLE800.
Remedy: 5-axis transformation and TOOLCARRIER activated at the same time.
61197 [Channel %1: ] Block %2: no swiveling in JOG --> active WO G%4 and
basic frames contain rotations
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE800.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program