
Overview of alarms 06/2009
NCK alarms
2-192
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
29033 [Channel %1: ] Axis exchange of axis %2 not possible, PLC axis
movement not yet completed
Parameters: %1 = Channel number
%2 = Axis
Definitions: A PLC axis has not yet reached its end position and cannot be returned to a channel or neutralized.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Wait until the axis has reached the end position or terminate the movement with delete distance to go.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Comentários a estes Manuais