Siemens SINUMERIK 802D sl Manual do Operador Página 273

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 340
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 272
Cycle alarms
06/2009 Overview of alarms
2-273
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62501 [Channel %1: ] Block %2: Speed has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE446
Remedy: Check speed and program a lower value in the NC program if necessary
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62502 [Channel %1: ] Block %2: Dresser %4, GWPS has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE421
Remedy: Check limit value for GWPS and program a lower value in the NC program if necessary
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62503 [Channel %1: ] Block %2: Dresser %4, speed has been limited
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE421
Remedy: Check speed and program a lower value in the NC program if necessary
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62900 [Channel %1: ] Block %2: Incorrect source file
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62901 [Channel %1: ] Block %2: Source file not available
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62902 [Channel %1: ] Block %2: Not yet implemented
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62903 [Channel %1: ] Block %2: Incorrect contour
Parameters: %1 = Channel number
%2 = Block number, label channel number
Vista de página 272
1 2 ... 268 269 270 271 272 273 274 275 276 277 278 ... 339 340

Comentários a estes Manuais

Sem comentários