Cycle alarms
06/2009 Overview of alarms
2-243
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61421 [Channel %1: ] Block %2: Software release of measuring cycles or NCK
inadequate or set up incorrectly --> error code %4
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy: Causes of error:
1. Error code = A -> _OVR[] - parameter field too small. Check GUD definition.
DEF CHAN REAL _OVR[72] (up to MZ06.03.xx.xx =32)
61422 [Channel %1: ] Block %2: Parameter _MVAR incorrect --> Error code: %4
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy: Causes of error:
1. Error code = A -> _MVAR = 9x identifier CYCLE996 measure kinematics
2. Error code = B -> Parameter for normalizing (_MVAR) incorrect
3. Error code = C -> Measurement variant "compute only" active, but rotary axis 1 or 2 not mea-
sured
(see also parameter _OVR[40])
61423 [Channel %1: ] Block %2: Parameter _TNUM not agreed or not created
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy: Causes of error:
1. Parameter CYCLE996 _TNUM incorrect or equals zero
2. No swivel data record created -> MD18088 = 0
61424 [Channel %1: ] Block %2: Parameter _SETVAL for diameter of calibration
ball incorrect
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy: Check parameter _SETVAL.
61425 [Channel %1: ] Block %2: Parameter for measuring axis rotary axis 1 or 2
incorrect -> Error code: %4
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy: Causes of error:
1. Error code = A -> Rotary axis number incorrect (1 or 2)
2. Error code = B -> No name agreed for rotary axis 1
3. Error code = C -> Rotary axis vector 1 equals zero
4. Error code = D -> No name agreed for rotary axis 2
5. Error code = E -> Rotary axis vector 2 equals zero
61426 [Channel %1: ] Block %2: Sum of the active offsets does not equal zero -
> Error code: %4
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy: Causes of error:
Check the overview of active offsets ($P_ACTFRAME)
1. Error code = A -> Sum of the translatory offsets of the geometry axes <> 0
2. Error code = B -> Sum of the fine offsets of the geometry axes <> 0
3. Error code = C -> Sum of the rotary components of the geometry axes <> 0
4. Error code = D -> Sum of the translatory offsets of rotary axis 1 <> 0
5. Error code = E -> Sum of the translatory offsets of rotary axis 2 <> 0