NCK alarms
06/2009 Overview of alarms
2-29
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
4343 [Channel %1: ] Attempt made to change the machine data of an active
transformation.
Parameters: %1 = Channel number
Definitions: An attempt was made to change the machine data of an active transformation and to activate the
machine data with RESET or NEWCONFIG.
Reaction: Interpreter stop
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Set valid machine data.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4346 [Channel %1: ] Invalid geoaxis assignment in machine data %2[%3]
Parameters: %1 = Channel number
%2 = Name of machine data
%3 = Transformation number
Definitions: MD2.... $MC_TRAFO_GEOAX_ASSIGN_TAB_... contains an invalid entry. The following causes for
the error are possible:
- The entry references a channel axis which does not exist.
- The entry is zero (no axis) but the transformation needs the relevant axis as a geometry axis.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Correct the entry in MD2.... $MC_TRAFO_GEOAX_ASSIGN_TAB_ or MD2....
$MC_TRAFO_AXES_IN_.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4350 [Channel %1: ] Axis identifier %2 machine data %3 not consistent with
machine data %4
Parameters: %1 = Channel number
%2 = String: Axis identifier
%3 = String: MD identifier
%4 = String: MD identifier
Definitions: MD32420 $MA_JOG_AND_POS_JERK_ENABLE (jerk limitation) and MD35240
$MA_ACCEL_TYPE_DRIVE (acceleration reduction) have been defined as the normal position for an
axis.
However, the two functions cannot be activated at the same time for one axis.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Resetting of MD32420
$MA_JOG_AND_POS_JERK_ENABLE or MD35240 $MA_ACCEL_TYPE_DRIVE.
Program Con-
tinuation:
Switch control OFF - ON.
4400 MD alteration will cause reorganization of buffered memory (Art %1),
(loss of data!) - %2
Parameters: %1 = Memory type
%2 = MD identifier, if required
Definitions: A machine data has been altered that configures the buffered memory. If the NCK powers up with the
altered data, this will lead to reorganization of the buffered memory and thus to the loss of all buffered
user data (part programs, tool data, GUD, leadscrew error compensation, ...)
Meaning of the 1st parameter
0x00 buffered memory (internal)
Vista de página 28