Overview of alarms 06/2009
PLC alarms
2-288
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
2.5 PLC alarms
400000 PLC STOP %1
Definitions: PLC not in cyclic mode. Travel with the machine is not possible.
%1: 1 Ready(User program has not been started)
2 Break (User program has been interrupted)
3 Error (Other PLC alarm with PLC Stop active)
Reaction: Alarm display.
Remedy: Rectify other PLC alarm;
Switch on menu in PLC stop position
or test user program.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
400001 System error %2
Definitions: %1 :Type number
With this alarm, internal alarm states are displayed that, in conjunction with the transferred error num-
ber, provide information on the cause and location of the error.
Reaction: PLC Stop
Remedy: Notify Siemens of this error together with the error message.
Program Con-
tinuation:
Switch control OFF - ON.
400002 System error %1
Definitions: %1 :Type number
Internal error states are displayed with this alarm. An error number is also specified to provide further
details about the cause and location of the error.
Reaction: PLC Stop
Remedy: Report this error to Siemens along with the type number.
Program Con-
tinuation:
Switch control OFF - ON.
400004 Code error: %2 network %1
Definitions: %1 :Network number
%2 :Internal error code, module type
The user program contains an operation which is not supported by the control.
Reaction: PLC Stop
Remedy: Modify and reload user program.
Program Con-
tinuation:
Switch control OFF - ON.
400006 Loss of remanent PLC data
Definitions: The following causes are possible:
Control handling (e.g. standard PLC deletion, power up with default values)
Control handling of power up with backed up data without backing up data in advance
Support time exceeded
Reaction: Alarm display.
Remedy: Update the data required.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
400007 Operand error: %2 network %1
Definitions: %1 :Network number
%2 :Module type
Reaction: PLC Stop
Remedy: The variable displayed must be checked in the user program for violation of the address range, imper-
missible data type and alignment errors.