Overview of alarms 06/2009
Cycle alarms
2-234
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61322 [Channel %1: ] Block %2: Check 4th number of _KNUM
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy: Check parameter _KNUM, _MVAR.
61323 [Channel %1: ] Block %2: Check 5th number of _KNUM
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy: Check parameter _KNUM, _MVAR.
61324 [Channel %1: ] Block %2: Check 6th number of _KNUM
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy: Check parameter _KNUM, _MVAR.
61325 [Channel %1: ] Block %2: Check measuring axis/auxiliary measuring axis
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter for metering shaft _MA has an incorrect value.
Alarm is triggered by: all measuring cycles except for CYCLE979.
Remedy: Check parameter _MA.
61326 [Channel %1: ] Block %2: Check measuring direction
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Parameter for measuring direction _MD has an incorrect value. Alarm is triggered: CYCLE973,
CYCLE976.
Remedy: Check parameter _MD.
61327 [Channel %1: ] Block %2: Program reset required
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: NC reset required.
Alarm is triggered: all measuring cycles except for CYCLE973, CYCLE976.
Remedy: Execute NC reset.
61328 [Channel %1: ] Block %2: Check D number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: D number in parameter _KNUM is 0.
The alarm can be triggered by all measuring cycles.
Remedy: Check parameter _KNUM.
61329 [Channel %1: ] Block %2: Check rotary axis
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No name assigned to the axis number specified under parameter _RA or axis not configured as rotary
axis. Alarm is triggered: CYCLE998.
Vista de página 233