Overview of alarms 06/2009
Cycle alarms
2-246
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: A tool offset value has to be programmed
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61504 [Channel %1: ] Block %2: _KNG incorrect for setup
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61505 [Channel %1: ] Block %2: retraction path < 1mm
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE420
Remedy: Increase retraction path
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61506 [Channel %1: ] Block %2: infeed path < 1mm
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: CYCLE420
Remedy: Increase infeed path
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61507 [Channel %1: ] Block %2: safety clearance < 1mm
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61508 [Channel %1: ] Block %2: Incorrect default setting for shoulder position
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61509 [Channel %1: ] Block %2: Incorrect default setting for dresser position
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycle: setup function
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61510 [Channel %1: ] Block %2: Test run feed is active
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm can be triggered by the following grinding cycles: CYCLE410, CYCLE411, CYCLE413,
CYCLE415, CYCLE420
Remedy: Switch off test run feed