List of action numbers 06/2009
3-296
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
No. 23, SINGLEBLOCK_PATH
No. 24, STARTPROG
No. 25, CHANNELSTARTPROG
No. 26, RESUMEPROG
Explanation Activate traversing single block (OPI variable and VDI signal: Activate single block)
Cause -
Remedy -
Explanation Start program processing (VDI signal: NC Start).
Cause 1. Program status active
2. An alarm reaction is pending which prevents a start or forces braking.
3. Reference point approach has not been performed yet.
Remedy − Execute condition for clearing alarm
− Reference point approach
Explanation Start program processing (channel communication, NC block: Start).
Cause 1. Program status active.
2. An alarm reaction is pending which prevents a start or forces braking.
3. Reference point approach has not been performed yet.
4. An incorrect operating mode has been selected. (only Automatic).
Remedy − Protect Start with WAITE
− Execute condition for clearing alarm
− Reference point approach
− Select program operating mode
Explanation Start continuation of program processing (VDI signal: NC Start).
Cause 1. Program status active
2. An alarm reaction is pending which prevents a start or forces braking.
3. Reference point approach has not been performed yet.
Remedy − Execute condition for clearing alarm.
− Reference point approach