NCK alarms
06/2009 Overview of alarms
2-169
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: - Check probe
- Check start positioning for measuring
- Check program
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
21740 Output value at analog output no. %1 has been limited
Parameters: %1 = No. of output
Definitions: The value range of the analog output n is limited by MD10330
$MN_FASTIO_ANA_OUTPUT_WEIGHT[n].
Reaction: Alarm display.
Remedy: With $A_OUTA[..] = x no greater values can be programmed than permitted in the respective machine
data.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
21760 [Channel %1: ] Block %2 too many auxiliary functions programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The number of programmed auxiliary functions has exceeded the maximum permissible amount. This
alarm can occur in conjunction with motion synchronous actions: The maximum number of auxiliary
functions must not be exceeded in motion block and motion synchronous actions.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
21800 [Channel %1: ] Workpiece setpoint %2 reached
Parameters: %1 = Channel number
%2 = Workpiece setpoint
Definitions: This alarm is activated via MD27880 $MC_PART_COUNTER, bit 1: The number of counted work-
pieces ($AC_ACTUAL_PARTS or $AC_SPECIAL_PARTS) is equal or already greater than the pro-
grammed value for the number of required workpieces ($AC_REQUIRED_PARTS). At the same time,
the channel VDI signal "Workpiece setpoint reached" is output. The value for the number of counted
workpieces ($AC_ACTUAL_PARTS) is reset, while the value of $AC_SPECIAL_PARTS is retained.
Note:
The setpoint/actual comparisons of the workpieces are only made after an NC start
under the condition that $AC_REQUIRED_PARTS > 0. If $AC_REQUIRED_PARTS
has a negative value, all workpiece counts activated through MD27880 $MC_PART_COUNTER are
frozen at the values they have reached,
and the nominal/actual comparison is discontinued.
Reaction: NC not ready.
Interface signals are set.
Alarm display.
Remedy: No program interrupt. Delete alarm display.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
22000 [Channel %1: ] Block %3 spindle %2 gear stage change not possible
Parameters: %1 = Channel number
%2 = Spindle number
%3 = Block number, label
Definitions: A gear stage change for the spindle will not be possible, if:
- thread cutting (G33, G34, G35) is active
- the spindle is active as master or slave spindle in a coupling
- the spindle is being positioned
Reaction: Interpreter stop
Comentários a estes Manuais