NCK alarms
06/2009 Overview of alarms
2-119
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: - Modify part program.
- If new cycle programs have been loaded on the NCK, you will normally need to increase the values
of MD18170 $MN_MM_NUM_MAX_FUNC_NAMES and MD18180
$MN_MM_NUM_MAX_FUNC_PARAM. See also the explanations for alarm 6010.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15180 [Channel %1: ] Block %2: Error on editing program %3 as INI/DEF file.
Parameters: %1 = Channel number
%2 = Block number, label
%3 = String
Definitions: Errors were found when processing an initialization program (INI file), or a GUD or macro definition
file (DEF file).
The error message which is then displayed refers to the program specified here.
Reaction: Alarm display.
Remedy: Correct the initialization program (INI file), or the GUD or macro definition file (DEF file).
In connection with Alarm 12380 or 12460, also change the memory configuration.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15185 [Channel %1: ] %2 errors in INI file
Parameters: %1 = Channel number
%2 = Number of detected errors
Definitions: Errors were found when processing initialization program _N_INITIAL_INI.
This alarm will also be output, if errors are found during editing of _N_INITIAL_INI in the GUD defini-
tion files or if errors are found on ramp-up in the macro definition files.
Reaction: NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Correct the INI or DEF file or correct the
MD and create a new INI file (via "Upload").
Program Con-
tinuation:
Switch control OFF - ON.
15190 [Channel %1: ] Block %2 not enough free memory for subroutine call
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The following deadlock has been found in the interpreter: Memory is needed for calling a subroutine.
The module memory is, however, empty and there is no prospect of module memory becoming free
again by executing the preprocessing/main run queue, because this queue is empty.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department. Increase machine data MD28010
$MC_MM_NUM_REORG_LUD_MODULES / MD28040 $MC_MM_LUD_VALUES_MEM / MD18210
$MN_MM_USER_MEM_DYNAMIC or program a preprocessing stop STOPRE before calling the sub-
routine.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
15300 [Channel %1: ] Block %2 invalid number-of-passed-blocks during block
search
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In the function "Block search with calculation" a negative number of passes has been entered in col-
umn P (number of passes). The permissible range of values is P 1 - P 9 999.
Reaction: Alarm display.
Remedy: Enter only positive number of passes within the range of values.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.