Technical Product Manual
Fault analysis and repairs 1318
2 Removing and fitting housing cover
Section 2: Removing and fitting housing cover • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 2 2–65
2.17.3 Separating plate
2.17.4 Secure contact with 318 warning LED (from 05.97)
Fig. 2-58 Secure contact with 318 warning LED (from 05.97)
Secure contact
Carry out the measures below to solve any problems with the warning LED (1), i.e. LED
lights up:
Fit the plate with support strips (2) (2-driver).
or
Fit the support (5) with support strips (6) (1-driver).
or
Fit and set the eccentric shaft (7) and bearing bracket (8).
(1- and 2-driver)
For fitting hints please refer to Section 3.6.9.
Remark
• If you must replace the separating plate as described under 2.17.1, replace
springs (6) and (8).
• If you must replace the separating plate as described under 2.17.2, springs
(6) and (8) can be reused.
• Push the springs in to the stop in the direction of the arrow (15)
using the flat-nose pliers (10).
• Then check whether the separating plate is working correctly.
1 Function control LED 5 Stylus guide
2 Support strips 6 Support strips
3 Separating plate 7 Eccentric shaft
4 Collar across full length 8 Bearing bracket
4
3
2
5
6
1