Technical Product Manual
Fault analysis and repairs 1318
4 Checking and adjusting
Section 4: Checking and adjusting • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 4 4–19
Fig. 4-18 Checking RPM recording
Correcting
Switch on the power.
Using tweezers correct the RPM stylus (3), Abb. 4-17.
Record again (7) and correct if necessary.
6
Network side
8
Adjustment circle
7
Recording
9
6
7
8
1
0
Remark
The RPM stylus must be corrected if the recording (7) is not as in Abb. 4-18
and the RPM indicator (5) does not point to the marking (4).
Note
If you cannot position it correctly check the operations to be done in
Chapter 2.11.7 "Inserting spur gears on the n measuring system" and in
Chapter 2.12.3 "Fitting n and v indicators".