Technical Product Manual
Fault analysis and repairs 1318
3 Removing and fitting housing
Section 3: Removing and fitting housing • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 3 3–27
3.8.2 Removing v contact carrier
Fig. 3-18 Contact carrier
Procedure
Remove the contact carrier (3) from the frame stud (4) in the direction of the
arrow (a).
Replacing the
contact springs (1)
Unsolder the wires (5).
Disengage the catch lugs (4) and remove the contact springs (1).
Push the new contact springs (1) into the contact carriers (2) until the catch
lugs (4) engage.
Solder the wires (5).
1 Contact springs 4 Frame stud
2 Catch lugs 5 Wires
3 Contact carrier
2
2
5
2
2
6
3
a
2
4
1
to 12.87
from
5
Remark
Ensure the wires are laid carefully (no strain).