Technical Product Manual
Fault analysis and repairs 1318
2 Removing and fitting housing cover
Section 2: Removing and fitting housing cover • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 2 2–9
2.3 Removing front parts
2.3.1 Removing bezel
Fig. 2-3 Removing bezel seals
Procedure
Press the bezel seals (1) in about 3-5 mm using a watchmaker's screwdriver,
max. Ø 1.9 mm.
When doing this, the sealing lugs (2) will break away.
Press used seals without sealing lugs (2) into the four sealing points
until these are flush with the cover.
Close the housing cover and remove the bezel.
Remove all bezel seals.
1 Bezel seals 2 Sealing lugs
2
2
1
1
Note
Bezel versions:
The 1318 Electronic Product Catalogue lists various versions for different ma-
nufacturers.
These are interchangeable.