Technical Product Manual
Fault analysis and repairs 1318
2 Removing and fitting housing cover
Section 2: Removing and fitting housing cover • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 2 2–37
Rivet the new contact kit (5) to the cover (6) so that it doesn’t have any play
using the rivet holder (4) and riveting die (3) for tubular rivets – outer diameter
2.0 mm.
2.10.2 Checking cover contact
Fig. 2-33 Checking cover contact
Procedure
Lift contact spring 1 (3) so that the plastic part (1) comes off the cover
slightly.
In this way the contacts (2) are securely closed.
Push the plastic part (1) down in the direction of the arrow (a) until the upper
edge
is flush with the cover base (6).
When doing this, the contact (2) must be open.
Use the adjustment lever (5) to correct this if necessary.
1 Plastic part 5 Adjustment lever
2 Contact 6 Cover base
3 Contact spring 1 7 Lug
4 Contact spring 2
1
2
4
a
6
5
7
from
3
Condition
Contact spring 1 (3) is parallel with the cover base (6).
or
The pre-tensioned contact spring 2 (4) sits on the lug (7).