Technical Product Manual
Fault analysis and repairs 1318
2 Removing and fitting housing cover
Section 2: Removing and fitting housing cover • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 2 2–11
2.3.3 Lock cylinder
2.3.3.1 Removing lock cylinder
Fig. 2-5 Removing lock cylinder
Procedure
Press the tumbler (2) down so that it points to (a) and turn the key in the direc-
tion of the arrow (b) until it reaches the stop.
Pull the lock cylinder and key out of the bezel (1).
2.3.3.2 Fitting lock cylinder
Fig. 2-6 Fitting lock cylinder
Procedure
Insert the lock cylinder and key (3) into the bezel.
When doing this, the protruding MS tumbler of the lock cylinder must point to the left
bezel edge.
Insert the lock cylinder until it is flush with the bezel, turn the key in the direc-
tion of the arrow (c) until the tumbler locks into place.
1 Bezel 2 Tumbler
a
1
b
2
3 Key with lock cylinder
3