Technical Product Manual
Fault analysis and repairs 1318
2 Removing and fitting housing cover
Section 2: Removing and fitting housing cover • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 2 2–25
2.8.4 Removing contact springs with holder on n measuring system
Fig. 2-20 Removing contact springs on n measuring system
Procedure
Remove the contact springs and holders (3) and (5) by disengaging the catch
lugs (4).
1 Contact carrier 4 Catch lug
2 Contact path 5 Contact spring with holder
3 Contract spring with holder 6 n frame
2
1
6
5
3
4
4
Remark
If this component is defective, replace the n frame (6) and integral potentiome-
ter unit.