3.16.3 Default setting for driver 2 coupling
Fig. 3-47 Default setting for driver 2 coupling
Procedure
Open the housing cover.
Undo the screw (10) slightly.
Set a gap of 1.5 mm between the coupling lever (12) and the plastic part (11).
Tighten the screw (10).
10 Screw 12 Coupling lever
11 Plastic part
10
11
12
1,5
+0,1