6 Additional equipment
6–12 Section 6 © Siemens VDO Trading GmbH TU00-1318-0200302
6.4 Additional equipment "45" – Two-level additional
stylus (connectors D1 / D2)
Basic application EDM recordings
For bar recording connect the clock generator "2154.02" between the
additional stylus control unit and the NEC Tachograph input.
(See Chapter 6.4.5)
6.4.1 Function
Fig. 6-9 Deflection – Level 1 / Level 2
Use a pulse memory if the pulse is < 50 ms. (See Chapter 6.4.7)
If the pulse is > 50 ms, the stylus magnet (5) deflects the additional stylus (2)
via the stylus lever (4).
With level 1 the stop (3) limits the bar length.
With level 2 current is supplied to the stop magnet (7) too. As a result, the stop's
(3) supporting point is modified.
EDM recordings
Level 1: Trace length 0.75 mm ± 0.2
Level 2: Trace length 1.45 mm ± 0.2
3
4
5
6
a
2
3.1
3
7
b
8
Level 1: Level 2
:
1
1 Working time stylus 5 Stylus magnet
2 Additional stylus 6 Screw
3 Stop 7 Stop magnet
4 Stylus lever 8 Screw