Technical Product Manual
Fault analysis and repairs 1318
4 Checking and adjusting
Section 4: Checking and adjusting • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 4 4–17
Fig. 4-15 Adjusting coupling lever
Fig. 4-16 Adjusting coupling lever
Correcting
Turn the Driver 2 knob to position " ".
Open the housing cover.
If the recording (3) is too low:
Using the Allen key (10) loosen the adjusting screw (11), reduce the gap (12)
and tighten the adjustment screw (11) again.
If the recording (4) is too high:
Using the Allen key (10) loosen the adjusting screw (11), increase the gap (12)
and tighten the adjustment screw (11) again.
To check this record for about 30 seconds again.
6 Coupling lever 9 Gap
7 Allen key 10 Stylus
8 Adjusting screw
10
ø 4
ap-
1
0
11
12
13
6
Note
The edges of the coupling lever (8) must not rub on the housing.