6 Additional equipment
6–14 Section 6 © Siemens VDO Trading GmbH TU00-1318-0200302
6.4.4 Checking recording
Fig. 6-11 Additional stylus - Checking and adjusting recording
Procedure
– Insert
1
the adjustment disc.
– Close the housing cover.
– Supply voltage to connectors "D1" and "D2" and the negative pole to "A5".
The recording (1) must be between the circular arcs (3) and (5).
Adjusting
– Using the adjustment tool correct the position of the stylus (6) in the direction
of arrow (a) or (c) or (b) or (d) (see Chapter4.1).
The stylus (6) must be aligned with the other styluses.
– Supply voltage to "D1" only.
– Check the recording (2) made.
The recording (2) must be between the circular arcs (9) and (10).
6
a
b
d
c
5
1 Recording 4 Circular arc
2 Recording 5 Circular arc
3 Circular arc 6 Stylus
1 1900.1501.054.030