2 Removing and fitting housing cover
2–44 Section 2 © Siemens VDO Trading GmbH TU00-1318-0200302
2.11.7 n measuring system - Inserting spur gears
Fig. 2-39 Inserting spur gears
Modified since 09.92
Spur gear gearing increased from 0.5 mm to 3.5 mm.
Procedure
Push the n stylus lever (1) in the direction of the arrow (A) to the stop.
Insert the spur gear (2).
The drilled holes a (3) must be opposite one another.
Insert the spur gear (5).
The drilled holes b (6) must be opposite one another.
Insert the spur gear (7).
The drilled holes (6) must be opposite one another.
1 n stylus lever 5 Spur gear
2 Spur gear 6 Drilled holes
3 Drilled holes a 7 Gear
4 Drilled holes b
2
1
3
4
5
6
7
A