6 Additional equipment
6–10 Section 6 © Siemens VDO Trading GmbH TU00-1318-0200302
6.3.3 Pulse output 4 imp/m (connector B8)
Fig. 6-7 Checking pulse output 4 imp/m
Conditions: TPH, TU00.1308.01 000 01, Chapter 6, page 22.
6.3.4 Checking pulse output 4 imp/m
Procedure
– Connect KTCO (1) and (3) to the electricity.
– On units (1) and (3) set the constant k = 8000 imp/km.
– Connect the pulse cable (2) to connector "B8" and connector "B3".
– Drive the unit (1) to 60 km/h on the test bench.
Unit (3) must indicate 30 km/h.
The display tolerance of unit (3) is ± 1 %.
A1 (+) / A5 (-)
B3
B8
2
1
KTCO 1
KTCO 2
3
2
B8
B3
4
1 KTCO 1 4 Trough connector
2 Pulse cable Connector "B3"
3 KTCO 2 Connector "B8"
Note
The pulse output is used to control vehicle functions that depend on distance
and speed.