2 Removing and fitting housing cover
2–36 Section 2 © Siemens VDO Trading GmbH TU00-1318-0200302
2.10 Cover contact
2.10.1 Replacing cover contact
Fig. 2-31 Removing cover contact
Fig. 2-32 Riveting cover contact
Procedure
Drill the tubular rivet head (1) out using a grooved bit.
Use the drilling support (2) for this.
Remove the contact kit (5) completely.
Remove any drilling chips.
1 Tubular rivet head 4 Rivet holder
2 Drilling support 5 Contact kit
3 Riveting dies 6 Cover
4
2
1
1
5