2 Removing and fitting housing cover
2–42 Section 2 © Siemens VDO Trading GmbH TU00-1318-0200302
2.11.5 Clockwork mechanism malfunction
Fig. 2-37 Modified cover plate with rotor cover
Modification
The lug (3) is no longer necessary.
There is a recess (4) instead.
Standard since 06.98. For order numbers please refer
to the 1318 Electronic Product Catalogue (EPC).
2
21
4
3
1
from
1 Cover plate 3 Lug
2 Rotor cover 4 Recess
Remark
There must be small gap between the rotor cover (2) on the bridge and the co-
ver plate/lamp plate (1).
• If not, use a round file to rework the cover plate.
When doing this, make sure not to damage the conductor.
• From 06.98 reworking is no longer necessary. The recess (4) is standard.