Technical Product Manual
Fault analysis and repairs 1318
3 Removing and fitting housing
Section 3: Removing and fitting housing • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 3 3–53
3.12.2 Modified contact set for warning device (up to 07.93)
Fig. 3-38 Modified contact set for warning device (up to 07.93)
Modified since 11.91
The guide lug (20) is discontinued on the rocker (4).
The contact spring (15) was increased from 0.1 mm to 0.15 mm.
The size of the bracket (13) was changed.
4 Rocker 16 Contact spring
13 Bracket 20 Guide lug
15 Contact spring
1
43
4
13
15
0.15 mm thick
16
4
20
16
15
13
to 10.91
Remark
In the event of a repair:
• Replace rocker (4), contact springs (15), (16) and bracket (13) together.
• Adjustment remains unchanged.