Technical Product Manual
Fault analysis and repairs 1318
3 Removing and fitting housing
Section 3: Removing and fitting housing • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 3 3–51
Modified since 05.90
The bearing bracket (1) is moulded to the frame plate (1.1).
Procedure
when removing
Lift up the wires (7).
Remove the securing paint in area (A).
Loosen the eccentric shaft (3) by rotating it.
Pull the bearing bracket (6) out in the direction of the arrow.
Lift the rocker (4) and push the bearing bracket (1) out of the guide.
Disengage the lugs (12) from the bracket (13).
Remove contact springs (15) and (16).
If contact springs (15) and (16) are faulty, unsolder wires (14) and (17) and replace.
Procedure
for installing
Put contact springs (15) and (16) onto the frame studs (10) and (11).
Secure the contact springs by putting the bracket (13) on.
Push the bearing bracket (1) on the frame plate into the frame guide.
Lug (2) points to the outer edge of the frame.
Push the rocker (4) and the eccentric shaft (3) together and insert them into
the bearing bracket (1) together.
Contact springs (13) and (14) must be located between rocker lugs (5) and (5.1).
Push the bearing bracket (6) onto the frame plate.
The lug must point in the direction of the arrow (a) towards the middle of the frame.
Move bearing brackets (1) and (6) until there is no play between the bearing
brackets and the rocker (4).
The frame lug (9) must be between the lugs (8).