Technical Product Manual
Fault analysis and repairs 1318
2 Removing and fitting housing cover
Section 2: Removing and fitting housing cover • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 2 2–45
2.12 Fitting dial components and indicators
2.12.1 Fitting dial components
Fig. 2-40 Fitting dial components
Procedure
Insert the flat cable (4) into the cut out (4).
Put the reflector (5) on the dial support (6) with the white side facing towards it.
Insert the complete unit (8) into the cover.
11
7
1
6
5
8
10
9
2
2
3
3
4
6
3
8
5
6.1
7
0.5
from
to 02.94
1 Flat cable 6.1 Dial support with chamfer
2 Stop springs 7 Dial
3 Diodes 8 Complete unit
4 Cut out 9 Diode holder
5 Reflector 10 Stop pin
6 Dial support 11 Adhesive tape
Note
When replacing the flat cable (1), always install the dial support with cham-
fer (6.1). It is standard from 02.94.
The diode holder (9), stop pin (10) and adhesive tape (11) connect the dial
support 6) and the dial (7).
The diodes (3) must engage into the holder (9) and the stop spring (2) into
the dial support (6).
Put a leather cloth or a clean cloth on the dial (7) to prevent it from getting dirty
(stains etc.).