3 Removing and fitting housing
3–46 Section 3 © Siemens VDO Trading GmbH TU00-1318-0200302
3.10.4 Removing and fitting socket housing contacts
Fig. 3-32 Removing and fitting socket housing contact
3.10.4.1 Pull contacts
Procedure
Grip the socket housing (1).
Unhook the catch lugs (6) by pressing the contact (2) against the socket hou-
sing with a screwdriver.
In this position push the special tool (5) into both openings (7) and unlock the
catch lugs (6).
Remove the screwdriver (4).
Pull the wire (3) and the contact (2) out of the socket housing (1).
3.10.4.2 Fitting contacts
Procedure
Push the contact (2) into the corresponding socket housing chamber (1)
until the catch lugs (6) engage.
By pulling gently on the wire (3) check that the catch lugs (6) have engaged.
1 Socket housing 5 Special tool
2 Contact 6 Catch lugs
3 Wire 7 Apertures
4 Screwdriver
4
3
2
1
3
5
7
6
Remark
• Do not pull on the contacts with too much force!
• If the catch lugs (6) do not unlock at the first attempt repeat the procedure.
Remark
With the contact (2) out use a screwdriver to put the two catch lugs (6) back
into the original position.