Siemens HydroRanger 200 Manual de Instruções Página 165

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 164
7ML19981FC01 HydroRanger 200 – INSTRUCTION MANUAL Page 151
mmmmm
Parameters
LCD Totalizer (P322 and P323)
Use these features to view, reset, or preset the eight-digit display totalizer when
Operation is set for OCM or Pumped Volume (P001 = 6 or 7). The eight-digit totalizer is
divided into two groups of four digits. The four least significant totalizer digits are stored
in P322, and the four most significant digits are stored in P323. Adjust these values
separately to set a new total.
Example:
P323 = 0017
P322 = 6.294
Totalizer Display = 00176.294
Totalizer units are dependent upon programming. Enter zero 0 (if required) to reset the
totalizer to zero. Alternatively, enter any other (applicable) value, to preset the totalizer to
the necessary value.
P322 LCD Total Low
View and/or alter the four least significant digits of the totalizer value.
P323 LCD Total High
View and/or alter the four most significant digits of the totalizer value.
Primary Index Global
Values Range: 0.000 to 9999
Related
P630 LCD Totalized Multiplier
P633 LCD Totalized Decimal Position
P737 Primary Reading
Primary Index Global
Values Range: 0.000 to 9999
Related
P630 LCD Totalized Multiplier
P633 LCD Totalized Decimal Position
P737 Primary Reading