NCK alarms/ISO alarms
06/2007 Overview of alarms
2-81
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Remedy: Enter the name of the facing axis in MD 20100 DIAMETER_AX_DEF for the spindles used.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10880 Channel %1 block %2 too many empty blocks between two traversing
blocks when inserting chamfers or radii
Parameters: %1 = channel number
%2 = block number, label
Definitions: Between 2 blocks containing the contour elements and to be joined with a chamfer or a radius (CHF,
RND), too many dummy blocks have been programmed without contour information.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Modify the part program so that the maximum permissible number of empty blocks is not exceeded.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10881 Channel %1 block %2 overflow of local block buffer when inserting
chamfers or radii
Parameters: %1 = channel number
%2 = block number, label
Definitions: Between 2 blocks containing the contour elements and to be joined with a chamfer or a radius (CHF,
RND), so many dummy blocks have been programmed without contour information that the internal
buffer is too small.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Modify the part program so that number of empty blocks is reduced.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
10882 Channel %1 block %2 activation of chamfers or radii (non-modal) without
traversing movement in the block
Parameters: %1 = channel number
%2 = block number, label
Definitions: No chamfer or radius has been inserted between 2 linear or circle contours (edge breaking) because:
There is no straight line or circle contour in the plane.
There is a movement outside of the plane.
A plane change has taken place.
The maximum permissible number of empty blocks with traversing information (dummy blocks) has
been exceeded.
Reaction: Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy: Correct the part program according to the error described above.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.