Overview of alarms 06/2007
NCK alarms/ISO alarms
2-104
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Remedy: Correct the name used (writing error)
$TC_DPCx, $TC_TPCx, $TC_MOPCx, $TC_MAPCx, $TC_MPPCx, $TC_DPCSx, $TC_TPCSx,
$TC_MOPCSx, $TC_MAPCSx, $TC_MPPCSx; with x=1,...10
These are the OEM parameters of the tools and magazines, the corresponding machine data value is
set to < 10, or the option 'TM OEM parameters' has not been set.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12553 Channel %1 block %2 name %3 option/function is not active
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions: The NC function that belongs to this language command is not active. Although the name of the lan-
guage command is known, the use of this language command in any program is rejected with this
alarm.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
• Correct the name used (typing error)
• Activate the NC function.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12554 Channel %1 block %2 replacement cycle %3 for the predefined
procedure is missing.
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Cycle name
Definitions: The replacement cycle that is to be called instead of the predefined procedure
is not present / unknown in the control.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC stop key and select the "Compensation block" function by pressing the PROGRAM
CORRECT softkey. The cursor will position itself in the faulty block.
- Correct the name used for the predefined procedure (write error)
- Or load the replacement cycle into one of the cycle directories (+ restart)
- Or set the machine data bit for the predefined procedure in $MN_COUPLE_CYCLE_MASK to 0 so
that the predefined procedure is executed again.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12555 Channel %1 block %2 function not available (identification %3)
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Detailed identification
Definitions: The identifier is not defined for this system.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block.
- Correct the name used (typing error)
- For low-level functions, use a more advanced software system
- Check definitions of variables, subroutines and macros
- Declare subroutine with EXTERN, load subroutine to SPF-Dir
- Check interface definition of subroutine
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.