List of action numbers 06/2007
3-360
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
No. 104, SINGLEAX_STOPALARM_MASTER
No. 105, SINGLEAX_RESUME_MASTER
No. 106, SINGLEAX_RESET_MASTER
No. 107, SINGLEAX_DELDIS_MASTER
No. 108, SINGLEAX_PLCCTRL_ON_MASTER
No. 109, SINGLEAX_PLCCTRL_OFF_MASTER
Explanation Stopping of a single axis movement by an alarm
Cause The axis is not controlled by the PLC. (exception old reaction with oscillation axis).
Remedy -
Explanation Continuation of a single-axis movement (VDI signal).
Cause The axis has not been stopped previously. Not for all axis types at present.
Remedy -
Explanation Interruption of a single-axis movement (VDI signal).
Cause The axis is not controlled by the PLC. Not for all axis types at present.
Remedy -
Explanation Deletion of distance-to-go of a single-axis movement (VDI signal).
Cause The axis is not controlled by the PLC. Not for all axis types at present.
Remedy -
Explanation Power ON: Axis is now controlled by the PLC (VDI signal).
Cause The axis is not controlled by the PLC. Not for all axis types at present.
Remedy -
Explanation Deactivate: Axis is now controlled by the PLC (VDI signal).
Cause The axis is not controlled by the PLC. Not for all axis types at present.
Remedy -