NCK alarms/ISO alarms
06/2007 Overview of alarms
2-35
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4345 Channel %1 invalid configuration in chained transformation no. %2
Parameters: %1 = Channel number
%2 = Transformation number
Definitions: A chained transformation is incorrectly configured (machine data $MC_TRACON_CHAIN_1 or
$MC_TRACON_CHAIN_2). The following causes for the error are possible:
- The list of transformations to be chained starts with a 0 (at least one entry not equal to zero is
required).
- The list of transformations to be chained contains the number of a transformation which does not
exist.
- The number of a transformation in the list is greater than or equal to the number of the chained trans-
formation. Example: The cascaded transformation is the fourth transformation in the system, i.e.
$MC_TRAFO_TYPE_4 = 8192. In this case, only values 1, 2 or 3 may be entered in the associated
list (e.g. $MC_TRACON_CHAIN_1[...]).
- The chaining setting is invalid. The following restrictions currently apply. A maximum of two transfor-
mations can be chained. The first transformation must be an orientation transformation, transmit,
peripheral curve transformation or inclined axis. The second transformation must be the inclined axis
transformation.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Set a valid transformation chain.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4346 Channel %1 invalid geoaxis assignment in machine data %2[%3]
Parameters: %1 = channel number
%2 = name of machine data
%3 = transformation number
Definitions: Machine data TRAFO_GEOAX_ASSIGN_TAB_1/2 contains an invalid entry.
The following causes for the error are possible:
- The entry references a channel axis that does not exist.
- The entry is zero (no axis) but the transformation needs the relevant axis as
a channel axis.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Correct the entry in TRAFO_GEOAX_ASSIGN_TAB_1/2 or TRAFO_AXES_IN_1/2.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4347 Channel %1 invalid channel axis assignment in machine data %2[%3]
Parameters: %1 = channel number
%2 = name of the machine data
%3 = transformation number
Definitions: Machine data TRAFO_AXIS_IN_1/2 contains an invalid entry.
The following causes for the error are possible:
- The entry references a channel axis which does not exist.
- The entry is zero (no axis) but the transformation needs the relevant axis as a channel axis.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Correct the entry in TRAFO_AXES_IN_1/2.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program