Overview of alarms 06/2007
NCK alarms/ISO alarms
2-202
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: No more than the specified number of outputs may be programmed in an NC block.
The quantity of hardware outputs is defined in the MD:
10360 FASTIO_DIG_NUM_OUTPUTS and
10310 FASTIO_ANA_NUM_OUTPUTS
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program fewer digital/analog outputs in one block. The specified maximum number applies in each
case separately for analog or digital outputs. If necessary, program two NC blocks.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17160 Channel %1 block %2 no tool selected
Parameters: %1 = channel number
%2 = block number, label
Definitions: An attempt has been made to access the current tool offset data although no tool was selected before-
hand.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program or activate a tool offset in the NC part program.
Example:
N100 G.. ... T5 D1 ... LF
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
17170 Channel %1 block %2 number of symbols too large
Parameters: %1 = channel number
%2 = block number, label
Definitions: The predefined symbols could not be read in during power-up.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: - SYSTEM ERROR – Please inform the authorized personnel/service department.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
17180 Channel %1 block %2 illegal D number
Parameters: %1 = channel number
%2 = block number, label
Definitions: In the displayed block, access is made to a D number (tool edge number) that is not initialized and
therefore is not available.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Check tool call in the NC part program:
Correct tool edge number D.. programmed?
If no tool edge number is specified, then D1 is automatically active.
All tool parameters defined?
The dimensions of the tool edge must have been entered previously either on the operator panel or
via the RS-232-C interface.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.