Overview of alarms 06/2007
NCK alarms/ISO alarms
2-52
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
8037 Option 'APC activation' not set
Definitions: The function 'Advanced Positioning Control' (APC) was activated in the control although the relevant
option has been set.
Reaction: NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Deactivate the function 'Advanced Positioning Control' (APC) in the drive.
Program Con-
tinuation:
Switch control OFF - ON.
8038 Option 'activation of more than %1 lead link axes' not set
Parameters: %1 = Number of axes
Definitions: The option for the number of lead link axes does not match the number of configured axes in the MD
$MA_AXCONF_ASSIGN_MASTER_NCU.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: - Buy option
- Configure fewer lead link axes
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
8040 Machine data %1 reset, corresponding option is not set
Parameters: %1 = String: MD identifier
Definitions: A machine data has been set that is locked via an option.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department.
For retrofitting the option, please refer to your machine manufacturer or to a sales representative of
SIEMENS AG, A&D MC.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
8041 Axis %1: MD %2 reset, corresponding option not sufficient
Parameters: %1 = axis number
%2 = string: MD identifier
Definitions: All of the axes selected in the machine data of the assigned option are used. The functions that belong
to the option have been selected for too many axes in the specified axial machine data.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
Program Con-
tinuation:
Switch control OFF - ON.
Comentários a estes Manuais