2.2 Cycle alarms
61000 Channel %1 block %2: No tool offset active
Parameters:
Definitions: Source (cycle):
SLOT1, SLOT2
POCKET3, POCKET4
CYCLE71
CYCLE72
CYCLE93 to CYCLE95
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: A tool must be programmed with corrections in the program called up.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61001 Channel %1 block %2: Thread lead incorrectly defined
Parameters:
Definitions: Source (cycle):
CYCLE84
CYCLE840
CYCLE97
CYCLE376T
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameters for thread size and check pitch information (contradict each other)
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61002 Channel %1 block %2: Type of machining incorrectly defined
Parameters:
Definitions: Source (cycle):
SLOT1, SLOT2
POCKET3, POCKET4
CYCLE71
CYCLE72
CYCLE93
CYCLE95
CYCLE97
Remedy: The machining type parameter VARI has been set to the wrong value and needs to be altered.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program