06/2007 System reactions on alarms
4-369
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl Diagnostics Manual, 06/2007 Edition
Name STOPATENDBYALARM
Effect Stop at end of block.
NC Stop on alarm at end of block
Name SHOWALARMAUTO
Effect The alarm is displayed whenever bit 0 of machine data ENABLE_ALARM_MASK is set.
The reaction should be set whenever an alarm should only occur during automatic
mode without manual operation by the user.
Alarm reaction in automatic mode
Name SHOWWARNING
Effect The alarm is displayed whenever bit 1 of machine data ENABLE_ALARM_MASK is set.
It is designed for warnings which should normally be suppressed.
Alarm view
Name ALLBAGS_NOREADY
Effect The Ready is canceled in all mode groups. The reaction thus corresponds to an NCK-
REACTIONVIEW|NOREADY, the difference being that the NC READY relay is not can-
celed and the corresponding VDI bit is not set. This is desirable in the event of an
emergency stop for example.
Mode group not ready
Name DELAY_ALARM_REACTION
Effect If this alarm reaction is configured in the alarm handler, all alarm reactions for alarms,
which occur at this point, are buffered channel-specifically and are, therefore, not active.
The alarms are displayed on the MMC. Mode group and NC-wide reactions are trans-
ferred. The reaction is cleared by activating the clearDelayReaction call or by an alarm,
which has configured NO_DELAY_ALARM_REACTION. This activates all the delayed
alarm reactions.
All channel-specific alarm reactions delayed on alarm, alarm display
Name NO_DELAY_ALARM_REACTION
Effect The DELAY_ALARM_REACTION state is canceled.
The alarm reaction delay is canceled.