NCK alarms/ISO alarms
06/2007 Overview of alarms
2-259
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Definitions: Not all encoder types and/or output types are available in the current software status.
MD 30240 ENC_TYPE= 0Simulation
= 1Signal generator
= 2Rectangular encoder
= 4EnDat absolute encoder
MD 30130 CTRLOUT_TYPE= 0Simulation
= 1Standard
Reaction: Mode group not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy: Check and correct in MD 32240 ENC_TYPE and/or MD 30130 CTRL_OUT_TYPE.
Program Con-
tinuation:
Switch control OFF - ON.
26014 Axis %1 machine data %2 invalid value
Parameters: %1 = axis name, spindle number
%2 = string: MD identifier
Definitions: MD contains an invalid value.
Reaction: NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Repeat entry with correct value and then Power On.
Program Con-
tinuation:
Switch control OFF - ON.
26015 Axis %1 machine data %2[%3] invalid value
Parameters: %1 = axis name, spindle number
%2 = string: MD identifier
%3 = index: MD array index
Definitions: MD contains an invalid value.
Reaction: NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Repeat entry with correct value and then Power On.
Program Con-
tinuation:
Switch control OFF - ON.
26016 Axis %1 machine data %2 invalid value
Parameters: %1 = axis name, spindle number
%2 = string: MD identifier
Definitions: Machine data contains an invalid value.
Reaction: NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.