Function Using buttons Using HART
Characteristic curve (lin., rad.)
(Not relevant for absolute
and gauge pressure)
Yes Yes
Customized characteristic curve No Yes
Diagnostic function No Yes
More operating functions for special applications are accessible through HART.
If a device does not have a display, its operations are limited. This is however not applicable
for selecting functions using HART.
6.2
Basic safety instructions
Note
Incorrect reproduction of the process pressure
If you have changed the basic functions of the pressure transmitter, the display and the
measurement output could be set such that the actual process pressure is not reproduced.
Therefore, check the basic parameters before commissioning.
6.3 Instructions for operation
The following rules are applicable for the operation of the pressure transmitter:
The device counts numerical values always in an ascending order step by step starting
from the least significant digit displayed.
If you keep the button pressed for a longer time, it counts the next higher digit displayed.
This procedure is used for fast coarse adjustment over a wide number range. Release the
[↑] or [↓] button again for fine adjustment. Press the button again.
Violations of the measured value limits are output on the display by
or .
The
keyboard must have been unlocked in order to operate the device using the keyboard.
If you are operating the transmitter locally, write access is denied through HART during this
time.
However, it is always possible to read the data, e.g. measured values.
Note
The setting is saved and the measured values are automatically displayed again if more
than two minutes have passed after a button was pressed for the last time.
The operating instructions in the "Local operation without display" section apply if the
device has been delivered with a blind cover.
Operation
6.3 Instructions for operation
SITRANS P, DS III series with HART
66 Operating Instructions, 09/2012, A5E00047092-08
Vista de página 67