A.4 Overview of HART operating structure
The following overview applies to the HART communicator operating structure.
2 Online 1 (PV meas) *)
2 (PV) status
3 Module type
4 Identification 1 Operation Unit 1 Tag
2 Long Tag --> M **)
3 Descriptor
4 Message
5 Date
2 Device 1 Manufacturer
2 Model
3 Device identification
4 Distributor
5 MLFB Order Number 1 MLFB Order No --> M
6 Measurement type
7 Fabrication-No
8 Final asembly number
9 Sensor serial number
10 Revisions 1 Universal rev.
2 Field device rev.
3 Software rev.
4 Hardware rev.
3 Basic Parameters 1 Pressure unit
2 LSL (Lower Sensor Limit)
3 USL (Upper Sensor Limit)
4 Minimum Span
5 LRV (Lower Range Value)
6 URV (Upper Range Value))
7 Pressure damping
8 Pressure xfer function xfer = transfer
5 Config Inp/Outp 1 Quick-Setup & Meas. 1 PV, Current, Status 1 (PV meas) *)
2 AO (analogue output)
3 (PV) % range
4 Status see ---> 6 Diagnosis/Service
5 Measurement type
2 Meas.Val. & Status 1 Pressure Values 1 Pressure
2 Pres status
3 Untrimmed pressure
4 Untrimmed pres status
2 Temperature Values 1 Sens-Temp
2 Sens-Temp status
3 Electr-Temp
4 Electr-Temp status
3 Level, Vol, Mass Values 1 Level
(shown if valid items) 2 Level status
3 Volume
4 Volume status
5 Mass
6 Mass status
4 Vol-, Mass- & Flow 1 Vol-Flow
(shown if valid items) 2 Vol-Flow status
3 Mass-Flow
4 Mass-Flow status
5 Appl & Stat 1 Customer
(shown if valid items) 2 Customer Status
3 Quick-Setup 1 Tag
2 Ext TAG --> M
3 PV is
4 (PV) unit
5 Position correction 1 Position corr --> M
6 LRV
7 URV
8 Pressure damping
9 Pressure xfer function
2 Input 1 Config Pres/Temp 1 Pressure sensor 1 Pressure
2 Untrimmed pres
3 Pressure units 1 Pres abs/rel
2 Pressure unit
3 Untrimmed pres unit
2 Temperature sensor 1 Sens-Temp
2 Electr-Temp
3 Temp units 1 Sens-Temp unit
2 Electr-Temp unit
3 Pres units see --> 1 Pressure sensor
4 Temp units see --> 2 Temperature sensor
2 Display Process Variables 1 Prozess variables 1 (PV measurement)
2 (PV) %rnge
3A O
4 (SV measurement)
5 (TV measurement)
6 (QV measurement)
3 Meas Switch/Mapper 1 measurement
2 PV is
3 SV is
4 TV is
5 QV is
6 (measurement) config 1 Input scaling 1 Pres abs/rel
e.g. Level 2 Pressure unit
3 Input LRV
4 Input URV
2 Level scaling 1 Level unit
e.g. Level scaling 2 Level LRV
3 Level URV to be continued
Appendix
A.4 Overview of HART operating structure
SITRANS P, DS III series with HART
Operating Instructions, 09/2012, A5E00047092-08 217