Configuring with Web Based Management
5.8 "Layer 3" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
245
5.8
"Layer 3" menu
5.8.1
NAT
5.8.1.1
Basic
Note
This tab is only available in the client mode.
On this page, you specify the basic settings for NAT.
Description
The page contains the following boxes:
Drop-down list "Interface"
From the drop-down list, select the required Ethernet interface.
Check box "Enable NAT"
Enable or disable NAT for the Ethernet interface. Can only be enabled if "Own" is set on
the client for "MAC Mode".
Input box "TCP Idle Timeout [s]"
Enter the required time in seconds. If no data exchange takes place, the TCP connection
is deleted from the translation table when this time has elapsed.
The range of values is 1 to 4294967295.
Default setting: 86400 seconds
Input box "UDP Idle Timeout [s]"
Enter the required time in seconds. If no data exchange takes place, the UDP connection
is deleted from the translation table when this time has elapsed.
The range of values is 1 to 4294967295.
Default setting: 300 seconds