Siemens IEEE802.11 Instruções de Operação Página 187

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 186
Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
187
Description
The table has the following rows:
State
Shows the status of the PLUG. The following are possible:
ACCEPTED
There is a PLUG with a valid and suitable configuration in the device.
NOT ACCEPTED
Invalid or incompatible configuration on the inserted PLUG.
NOT PRESENT
There is no C-PLUG or KEY-PLUG inserted in the device.
FACTORY
PLUG is inserted and does not contain a configuration. This status is also displayed
when the PLUG was formatted during operation.
MISSING
There is no PLUG inserted. Functions are configured on the device for which a license
is required.
Device Group
Shows the SIMATIC NET product line that used the C-PLUG or KEY-PLUG previously.
Device Type
Shows the device type within the product line that used the C-PLUG or KEY-PLUG
previously.
Configuration Revision
The version of the configuration structure. This information relates to the configuration
options supported by the device and has nothing to do with the concrete hardware
configuration. This revision information does not therefore change if you add or remove
additional components (modules or extenders), it can, however, change if you update the
firmware.
File System
Displays the type of file system on the PLUG.
NOTICE
New file system UBI
As of SCALANCE W firmware version 2.0 and SCALANCE X500 firmware version 3.0,
UBI is the standard file system for the C-PLUG or KEY-PLUG. If a C-PLUG with the
previous file system IECP is detected in such a device, this C-PLUG will be formatted
for the UBI file system and the data will be rewritten to the C-PLUG.
This change in the file system also occurs following a firmware update to V2.0 with
SCALANCE W or to V3.0 with SCALANCE X500. A downgrade to the previous version
of the firmware then presents a problem. The firmware can neither read nor write the C-
PLUG or KEY-PLUG and it is not even possible to "Erase PLUG to Factory Default".
File System Size [Byte]
Displays the maximum storage capacity of the file system on the PLUG.
Vista de página 186
1 2 ... 182 183 184 185 186 187 188 189 190 191 192 ... 291 292

Comentários a estes Manuais

Sem comentários