Configuring with Web Based Management
5.6 "Interfaces" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
203
Additional Attenuation [dB]
Here, specify the additional attenuation caused, for example, by an additional splitter.
Antenna Mode
Specify the use of the antenna. For antenna connector 1 (R1 A1 and R2 A1), the entry
cannot be changed.
Tx
For sending only
Rx
For receiving only
Rx\Tx
For receiving and sending
The following table shows which combinations are possible:
R1 A1
R2 A1
R1 A2
R2 A2
Rx\Tx
Rx\Tx
Rx\Tx
Rx
Rx\Tx
Tx
Rx\Tx --
1)
1) Antenna type "50 Ohms Termination Impedance"
Steps in configuration
To configure one or more antennas, follow the steps below:
1. For the first antenna connector (R1 A1) in the "Antenna Type" drop-down list, select the
type of antenna.
2. In the "Cable Length" input box, enter the length of the connecting cable you are using in
meters. For antenna connector 1 (R1 A1 and R2 A1), the "Antenna Mode" cannot be
changed.
3. For further antenna connectors (e.g. R1 A2), select the type of antenna from the
"Antenna Type" drop-down list.
4. In the "Cable Length" input box, enter the length of the connecting cable you are using in
meters.
5. Select the use of the antenna from the "Antenna Mode" drop-down list.
6. Repeat steps 3 to 5 for further antenna connectors.
7. Click the "Set Values" button.