Siemens IEEE802.11 Instruções de Operação Página 243

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 242
Configuring with Web Based Management
5.7 "Layer 2" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
243
Description
The table has the following columns:
Port
Shows the available ports.
Setting
Specify whether the port should block or forward outgoing DCP frames. You have the
following options available:
Block
No outgoing DCP frames are forwarded via this port. It is nevertheless still possible to
receive via this port.
Forward
The DCP frames are forwarded via this port.
Procedure
1. Specify whether the port blocks or forwards the DCP frames.
2. Click the "Set Values" button.
5.7.5
LLDP
Link Layer Discovery Protocol (LLDP)
PROFINET uses the LLDP protocol for topology diagnostics.
In the factory settings, LLDP is activated on the interface, in other words LLDP frames are
sent and received. LLDP is supported only by the Ethernet interface and by the SFP
interface P1.
On this WBM page, you activate or deactivate the sending or receiving of LLDP frames on
the interface.
Vista de página 242
1 2 ... 238 239 240 241 242 243 244 245 246 247 248 ... 291 292