Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
Configuration Manual, 11/2014, C79000-G8976-C323-03
185
If a client is to be used as a PNIO device, the MAC address of the client must be specified as
follows (MAC Mode):
●
In the network beyond the device, only IP communication and no PNIO is possible.
●
The client and the devices downstream from it can be used as PNIO devices.
"Automatic" or "Manual" is configured as the MAC mode for a client, this device cannot
be used as a PNIO device.
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is present at one second intervals. If it is
detected that the PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted
in the device, the device changes to a defined error state following the restart. With
SCALANCE W, the available wireless interfaces are deactivated in this case.
If the device was configured at some time with a PLUG, the device can no longer be used
without this PLUG. To be able to use the device again, reset the device to the factory
settings.
Information about the configuration of the C-PLUG / KEY-PLUG
This page provides detailed information about the configuration stored on the C-PLUG or
KEY-PLUG. It is also possible to reset the PLUG to "factory defaults" or to load it with new
contents.
Note
The action is only executed after you click the "Set Values" button.
The action cannot be undone.
If you decide against executing the function after making your
selection, click the "Refresh"
button. As a result the data of this page is read from the device again and the selection is
canceled.