Siemens IEEE802.11 Instruções de Operação Página 128

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 127
Configuring with Web Based Management
5.5 "System" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
128 Configuration Manual, 11/2014, C79000-G8976-C323-03
5.5.3
Agent IP
Configuration of the IP addresses
On this WBM page, you configure the IP address for the device.
Description
The page contains the following boxes:
IP Assignment Method
Shows how the IP address is assigned.
Static
The IP address is static. You enter the IP settings in the "IP Address" and "Subnet
Mask" input boxes.
Dynamic (DHCP)
The device obtains a dynamic IP address from a DHCP server.
"IP Address" input box
Enter the IP address of the device.
After clicking the "Set Values" button, this IP address is also displayed in the address bar
of the Web browser. If this does not take place automatically, you will need to enter the IP
address in the address bar of the Web browser manually.
"Subnet Mask" input box
Enter the subnet mask of the device.
"Default Gateway" input box
Enter the IP address of the default gateway to be able to communicate with devices in
another subnet, for example diagnostics stations, e-mail server.