6/74
Siemens IK PI · 2015
Industrial Wireless Communication
IWLAN – Controller and Controller Access Points IEEE 802.11n
SCALANCE W788C M12 controller access points for indoor use
■
Overview
• SCALANCE W788C-2 M12 controller-based access points
can only be operated on the SCALANCE WLC IWLAN
Controller
• Particularly suitable for industrial applications without control
cabinets
■
Design
• Rugged aluminum enclosure, shock and vibration-proof,
for high mechanical requirements
• High IP65 degree of protection against dust and water jets
• For use at ambient temperatures from -20 °C to +60 °C
• 6 x N-Connect sockets for the connection of direct mountable
and remote antennas
• Antenna placement optimized for the 3x3 MIMO technology;
the antennas do not interfere with each other when they are
mounted directly on the device
• Suitable for 2.4 GHz and 5 GHz
• 1 x M12 connection for 10/100/1 000 Mbit/s with Power-over-
Ethernet according to IEEE 802.3at
• 1 x M12 socket for power supply (24 V DC)
• Function LEDs for optical signaling of faults and operating
states
• Mounting: Wall, S7-1500 mounting rail, S7-300 mounting rail,
or on 35 mm standard mounting rail
Design and interfaces of the SCALANCE W788C-2 M12 controller-based
access points
Product versions
SCALANCE W788C-2 M12 (controller-based)
• Two wireless cards permanently installed in the device
3x N-Connect (female) connections for antennas
3x N-Connect
(female)
connections
for antennas
24 V DC
connection
M12 connection
(Gigabit)
nprXWZWZ[X